ChemWell® 2910 features:

  • 200 tests per hour
  • No carry-over
  • Liquid sensing probe tip
  • 8-well wash head
  • Level-sensing wash, rinse, and waste bottles
  • LIS, STAT
  • QC tracking
  • Self-monitoring mechanics and optics
  • Auto dilute and retest for over-range samples
  • Reaction Volume <250uL
  • No custom disposables
  • IAD filters
  • Creates automatic service reports
  • Edit standard curves

Rev 6.3 Software features and improvements:

  • Note: Rev 6.3 enhancements require Main091 firmware or newer for full functionality.
  • Added the ability to wash wells in EIA mode, making it easier to wash the wells after running a self test, or to use the ChemWell as a washer if needed, without switching to Chemistry mode from EIA mode.
  • Tool tip buttons added.
  • "Auto retest" samples if out of range.
  • "Self Test" chooses the best filters if custom filters are installed.
  • ChemWell Pack utility now has many more options and flexibility.
  • "End of Day" warns user to place DI water in Rinse bottle and increases prime cycles for better cleaning of wash head.
  • If pre-diluting in sample rack, new option allows choice of making two tubes for duplicates or one tube for both .
  • EIA wash sub-steps are now editable.
  • Temperature on/off switch is now programmable in EIA incubate steps.
  • Software offers optional second wash bottle.
  • Sample Rack can be changed in the same way that Reagent rack can be changed, if more than one is used.
  • Log base 10 is now available for axis choice in mulitple-point assays.
  • Options available for date display.
  • Added custom Report Creator to software; available through the "Utilities" menu.

Rev 6.2 Software features and improvements:

  • Self Test Mode - Performance tests, filter voltage checks, and stored blank verification can all be run from a central location with the click of a button.
  • Improved Assay Timing - Assay timing is automatically optimized by ChemWell Manager, eliminating potential conflicts between assays with differing incubation/read times.
  • Custom Report Utility - Allows users to create their own custom reports from start to finish.

Rev 6.1 Software features and improvements:

  • Intuitive new interface
  • Continuous Loading - Instead of collecting a batch of specimens for a run, tests and samples can now be run on demand, even while other tests are running.
  • Calibrators and Controls can be run at any time and independently of tests, allowing you to update stored curves and validate tests as required. If tests associated with the newly loaded calibrator were already running, the sample concentrations for that test will be automatically adjusted for the new curve.
  • Results for individual samples can be accepted or re-run for verification, simply by clicking a button; no need to set up a new job or reposition sample cups when re-testing.
  • Sample and Reagent positions can be easily relocated using the Windows® "drag and drop" feature.
  • Assay programming is greatly simplified.
  • Report formats are easier to modify.

ChemWell® is a registered trademark of Awareness Technology, Inc. All rights reserved.